39148102 50Ah Prismatic Sodium-ion Battery Cell
$18/pcs
Specification 39148102 50Ah Prismatic Sodium-ion Battery
Cell Type:39148102 50Ah
2. Electrical specification
2.1. General
No. | Parameter | Specification | Condition |
2.1.1 | Typical capacity |
50Ah |
Refer to 2.2&2.3 standard charge and discharge procedure |
2.1.2 | Platform voltage |
2.9V | Refer to 2.2&2.3 standard charge and discharge procedure |
2.1.3 | Operating voltage | 1.5~3.9V | N.A |
2.1.4 | Impedance (1KHz) |
0.60±0.05mΩ | Fresh cell(50%SOC) |
2.1.5 | Shipping status |
50% SOC |
N.A |
2.1.6 | Residual capacity loss |
Per month ≤3.5% |
Fresh cell after 3month, 50%SOC, 25±2°C storage |
2.1.7 | Operating temperature (charging) |
0~60°C |
Reference to paragraph 2.2 |
No. | Parameter | Specification | Condition |
2.1.8 |
Operating temperature (discharge) |
-40~60°C |
Reference to paragraph 2.3 |
2.1.9 | Cell Weight | 1.12±0.05Kg | N.A. |
2.1.10 | Storage Temp. |
-30~60°C |
Storage ambient humidity < 85% ROH, no condensation |
2.1.11 |
Typical dimension (W* H* T) | (Width) : 148±0.5mm (Height) :102±0.5mm (Thickness):39.5±0.5mm |
Thickness with compression force (300±20 Kgf), Height with Terminal, BOL(Reference to item 8) |
2.1.12 | SOC Rest SOC | ≥5% |
SOC interval without load or charging |
2.1.13 | Altitude | ≤2000m | N.A. |
2.1.14 |
Cycle performance |
≥4000Cycles |
25±2°C, cycle test by 1.8-3.8V charge and discharge method under 300±20Kgf preload |
2.1.15 | Storage fading | ≤5% | 25±2°C, standard charging to 100% SOC storage under 300±20Kgf preload for six month |
2.2. Charging/Parameter
No. |
Parameter |
Specification |
Condition |
2.2.1 | Standard charge current | 0.5C | 25±2oC |
2.2.2 | Maximum charge current(continuous) |
1C |
25±2oC |
2.2.3 | Standard charge voltage | Cell max voltage 3.9V |
25±2oC |
2.2.4 | Standard charge method | 0.5C constant current constant voltage charge to 3.9V, cut-off current 0.05C, rest 30min. | |
2.2.5 | Standard charge temperature | 25±2°C | Cell Temperature |
2.2.6 | Absolute charging temperature (Cell Temperature) |
0~60°C | No matter what charge mode the battery is in, stop charging once the cell temperature exceeds absolute charge temperature range. |
2.2.7 | Absolute charging voltage |
Max3.9V | No matter what charge mode the battery is in, stop charging once the cell voltage exceeds absolute charge voltage. |
Contact: Rena,Bill gao
Phone: +86-18902841176 | +86-18320402423
Tel: +86-18902841176 | +86-18320402423
Email: billgao@battery-manufacturers.com
Add: 301-320A59, Rongxing Building, Bantian Street, Longgang District, Shenzhen City,China.